What are the possible causes of lumps formation in cement silo?

14 Sep,2015 UTC+8 Views:


1. The temperature of the cement grinding in output from the mill is lower than the dew point temperature, (check humidity of corrective materials for mixture to the clinker).

2. Infiltration of water into the storage silos, (the silos must have the roof waterproofed)

3. The cement silos are maintained for too long without moving (to do frequent extraction + grinding) the fineness of the cement value Blaine very high, also very fine.

4. You can use the grinding additives adjuvants, which increase the production of the mill facilitate the sliding of the concrete through the raceways of transport to the silo, keep the cement fluid for 10-15 days max (it is implied that in this case the silos must be free of infiltration of rainwater).

5. Other solutions are completely harmful, forcing Enterprises unnecessary expenses, without solving the underlying problem.

6. Make the complex installations and add additional maintenance.

7. Must bear in mind that plants are simpler and better work, require a short maintenance much lower.

8. it is implied that the best solutions are those made during the study and the choice of implants before the construction of the factory, it is essential to always contact real professionals and much less to the vendors of plant and machinery.